When I open a new project on version 2024.3, I save the project and then reopen it, finding it on version 2024.2. !!!
When I open a new project on version 2024.3, I save the project and then reopen it, finding it on version 2024.2. !!!
I open a new project on 2024.3 and save it on the desktop.
I close the Aximmetry , go to the desktop, open the project that I saved. I find it on the old version 2024.2 , so it does not work with the new version of Unreal. So I open the Aximmetry 2024.3 then I open the project on the desktop. !!!
Hi,
There are indeed some issues with the file association of .xcomp files. This will probably be addressed in the next Aximmetry release.
Until then, you should be able to fix it in the Windows Registry.
To do this, open the Start menu and type "Registry Editor."
Launch the program, and navigate to:
HKEY_CLASSES_ROOT\Aximmetry Compound\shell\open\command
Rename the key found there to the path of the Aximmetry.Composer.exe file that you want to use.
Warmest regards,
Hi,
The new Aximmetry 2025.1.0 Beta includes the Version Manager app, which allows you to change the file association of .xcomp files. It also simplifies the management of multiple Aximmetry versions on one computer.
You can download this new Beta version from: https://my.aximmetry.com/User/MyDownloads
Warmest regards,
Unfortunately, there are many problems in the 2024.3 version. I hope they will be solved.