Aximmetry Composer hangs on start-up (even after a reboot) after clicking start on the popup panel. This used to work fine.
Any solution?
Steps:
1. Start Aximmetry Composer
2. Click start on this popup as usual
3. Aximmetry hangs on this screen indefinitely
Here is the log output:
[20:07:44] [Main] Pre-registering plugin AximmetryEngine.Plugins.StudioFull.dll
[20:07:44] [Main] Adding device type CameraTracking: Manual
[20:07:44] [Main] Adding device type CameraTracking: AGTP
[20:07:44] [Main] Adding device type CameraTracking: AGTP-OSC
[20:07:44] [Main] Adding device type CameraTracking: MoSysSerial (hidden)
[20:07:44] [Main] Adding device type CameraTracking: MoSysUDP (hidden)
[20:07:44] [Main] Adding device type CameraTracking: Mo-Sys
[20:07:44] [Main] Adding device type CameraTracking: Stype
[20:07:44] [Main] Adding device type CameraTracking: TrackMen
[20:07:44] [Main] Adding device type CameraTracking: Ncam
[20:07:44] [Main] Adding device type CameraTracking: Camix
[20:07:44] [Main] Adding device type ZoomEncoder: Camix
[20:07:44] [Main] Adding device type CameraTracking: Augmenta
[20:07:44] [Main] Adding device type CameraTracking: RocketLabUDP (hidden)
[20:07:44] [Main] Adding device type CameraTracking: RocketLab
[20:07:44] [Main] Adding device type CameraTracking: FreeDSerial (hidden)
[20:07:44] [Main] Adding device type CameraTracking: FreeDUDP (hidden)
[20:07:44] [Main] Adding device type CameraTracking: Free-D
[20:07:44] [Main] Adding device type ZoomEncoder: Free-D
[20:07:44] [Main] Adding device type CameraTracking: Visca
[20:07:44] [Main] Adding device type ZoomEncoder: Visca
[20:07:44] [Main] Adding device type CameraTracking: Vanishing Vector
[20:07:44] [Main] Adding device type ZoomEncoder: Vanishing Viper
[20:07:44] [Main] Adding device type ZoomEncoder: LonetMain (hidden)
[20:07:44] [Main] Adding device type ZoomEncoder: Lonet
[20:07:44] [Main] Adding device type ZoomEncoder: Lonet2Main (hidden)
[20:07:44] [Main] Adding device type ZoomEncoder: Lonet2
[20:07:44] [Main] Adding device type CameraTracking: ThomaMain (hidden)
[20:07:44] [Main] Adding device type CameraTracking: Thoma
[20:07:44] [Main] Adding device type CameraTracking: zLense
[20:07:45] [Main] Opening device "VideoOut: Blackmagic: DeckLink Duo (1)"
[20:07:45] [Main] Setting mode "1080p23.98" for device "VideoOut: Blackmagic: DeckLink Duo (1)"
[20:07:45] [Main] Opening device "VideoOut: Blackmagic: DeckLink Duo (2)"
[20:07:45] [Main] Setting mode "1080p23.98" for device "VideoOut: Blackmagic: DeckLink Duo (2)"
[20:07:46] [Main] Opening device "VideoOut: Blackmagic: DeckLink Duo (3)"
[20:07:46] [Main] Setting mode "1080p23.98" for device "VideoOut: Blackmagic: DeckLink Duo (3)"
[20:07:46] [Main] Opening device "VideoOut: Blackmagic: DeckLink Duo (4)"
[20:07:46] [Main] Setting mode "1080p23.98" for device "VideoOut: Blackmagic: DeckLink Duo (4)"
[20:07:46] [Main] Opening device "VideoOut: NDI: MAIN"
[20:07:46] [VideoOut: NDI: MAIN] Thread started
[20:07:46] [Main] Setting mode "1080p23.976" for device "VideoOut: NDI: MAIN"
[20:08:20] [Main] Closing device "VideoOut: Blackmagic: DeckLink Duo (1)"
[20:08:20] [Main] Closing device "VideoOut: Blackmagic: DeckLink Duo (2)"
[20:08:21] [Main] Closing device "VideoOut: Blackmagic: DeckLink Duo (3)"
[20:08:21] [Main] Closing device "VideoOut: Blackmagic: DeckLink Duo (4)"
[20:08:21] [Main] Closing device "VideoOut: NDI: MAIN"
[20:08:21] [VideoOut: NDI: MAIN] Thread terminated
Note Aximmetry Camera calibrator starts fine. We did a test.
A repair install did not help either. Aximmetry Composter Startup configuration is hanging.