Aximmetry DMX Input

Studio Operators Bugs Composer External Control

 

Hello!

Today we have tried to test DMX input via art net.

We use Avolites Titan Mobile light desk for that

Aximmetry IP for test is 2.0.0.2\24  Titan Mpbile PC ip is 2.0.0.1\24

Titan mobile can see aximetry artnet on its interface

Aximmetry also can see Titan Mobile as DMX(Artnet) Out (as detected device in start menu)

In my compound i try to set controlable feature with DMX input module.

I set 0 net 0 subnet 0 universe and channel 200 (for example) but on output pin of DMX input module nothing happens (just zero value)

I run ArtNetominator software to see what going on Artnet in complex and see that signal from titan mobile on channel 200 comes fine.

So i'm confused

How we can properly setup Aximmetry with DMX (Artnet) input?

   Alexander Zhivykh

 
Profile Image
nachodosene
6/29/2020 11:15:51 PM
  -  

hello


i have the same problem

output works well

input dont works


anyone could help us????

 
Profile Image
Aximmetry
7/8/2020 3:13:38 PM
  -  

When you setup the DMX Input module did you select ArtNet: as Device?

 
Profile Image
Alexander Zhivykh
7/14/2020 9:28:51 AM
  -  

Yes. We set Artnet as device at starting dialog at "device mapper" menu and choose Titan Mobile At "Manage Device" menu for DMX out but no message from input

 
Profile Image
Aximmetry
7/16/2020 7:12:36 PM
  -  

Hi Alexander,
Unfortunately we discovered an issue in Aximmetry that prevents using ArtNet input.
We apoligize for that. In a few days we'll release a patch that will fix this issue among others.