Zoom data delayed from Loled Virtual

 

Ok if have been at this for the last few months. Calibrating a Fujinon lens via the Lens Calibration proces. That all works fine. I got a good sync on the camera and Aximmerty. But the zoom ... I don't know anymore. Set a delay in the Calibration app. In the mapping data in Aximmerty. But Zoom data from Aximmerty is always a few frames behind. What switch do I need to flip to get this working. I dial in a delay but nothing happens.Is it something in the LONED Server? Data device mapping? I'm lost!

Great to hear some tips.

Cheers,
Harmen

   harmenvantloo

 
Profile Image
Eifert@Aximmetry
  -  

Hi Harmen,

When using a single hardware that sends both tracking and zoom data to Aximmetry, in order to be able to adjust the tracking delay and zoom delay parameters separately, you need to specify the same hardware both as tracking device and zoom device, you then can specify different values for above said parameters.
Sorry for the inconvenience, we try really hard to keep our knowledge base documentation up-to-date, but there's always a certain delay to refreshing our documentation compared to the appearance of fixes and improvements.

Please, let us know please if the problem with the zoom delay still persists.