The manufacturer of the robotic arm uses the Trackmen protocol, and the lens file has already been selected in the robotic arm's data box, outputting calibrated tracking data. Do I need to do anything in the input settings of Aximmetry? Currently, there is no push-pull tracking, but the tracking works very well at the wide-angle end of the lens. I have enabled "External Lens Data," otherwise the tracking drifts. The "Calib File" and "Zoom Device" options are not selected.
Question:
Given this setup, what adjustments should I make in Aximmetry's input settings to ensure proper zoom tracking?
Hi,
It seems your issue is that the zoom level doesn't change in Aximmetry even though you adjust it on your tracked camera.
To troubleshoot this, try using a single Camera Tracking module in Aximmetry. Check whether the values of the Zoom Sensor and the Zoom Factor pins change when you modify the zoom on your camera. Keep in mind that the Zoom Sensor displays the uncalibrated zoom value, while the Zoom Factor shows the calibrated value. You can find more details here: https://aximmetry.com/learn/virtual-production-workflow/tracking/setting-up-the-communication/how-to-set-up-tracking-systems-in-aximmetry/
Warmest regards,